GENERAL SAFETY REGULATIONS

IN CASE OF INSTALLATION ON OPEN
TANK SYSTEMS
The connections, commissioning and veri cation of proper
operation of the thermo replace must be carried out by quali-
ed personnel, who can implement all connections in accor-
dance with the laws in force, particularly with Italian D.M 37
Law No. 6 90, apart from complying with these instructions.
For installations implemented outside Italy, please refer to the
local regulations in the country of use.
The thermo replace and the system are lled with water that
ows from the water inlet pipe (the diameter must not be less
than 18 mm) to the open expansion tank.
All the vents of the radiators must be opened during this
phase so as to prevent air pockets from forming in the system,
which would obstruct the circulation of water.
NB:
The open tank should be positioned at a height greater than
3 m higher than the highest component of the primary circuit
and less than 15 m from the edge of the thermo replace.
In any case, the tank must be high enough to create a greater
pressure than that produced by the pump (circulator).
The system must never be lled directly from the water
mains as the pressure may be greater than that stipulated on
the data plate of the thermo replace, with resulting damage
to the thermo replace itself.
The safety pipe to the expansion tank must allow the water
to ow freely without shut-off valves and be appropriately
insulated to prevent the water inside from freezing, which
would compromise the connection.
The water inlet pipe must not have taps nor curves.
The maximum operating pressure must not exceed 1.5 bar
The testing pressure is 3 bar.
It is a good idea to add an anti-freeze liquid to the water
contained in the system or to observe standard UNI 8065.
Never ignite the re in the thermo replace (not even as a
test) unless the system is lled with water as this could cause
irreparable damage.
Connect the drains of the thermal relief valve (TRV) and
the safety valve (SV) (diagrams are found on the following
pages).
The ow test of the system must be carried out with the
expansion tank open.
It is recommended to install a 6 bar safety valve on the hot
sanitary water circuit so as to drain any excessive increase in
the volume of the water in the heat exchanger.
Place all the components of the system (circulator, heat
exchanger, valves, etc.) in easily accessible points for routine
and special maintenance procedures.
WATER TREATMENT
If need be, antifreeze, descaling and anticorrosive solutions
are to be added to the water.
A softener must be used if the hardness of the water used to
re ll and top-up the system exceeds 35°f (French degrees).
IN CASE OF INSTALLATION ON CLOSED
TANK SYSTEMS
(provisions in addition to those provided for open tank
systems)
Be careful not to exceed 1.5 bar when lling the system.
Only if a thermal relief valve actuates the coil can the
replace be installed on a CLOSED TANK system (version
marked with the abbreviation CS).
When connecting a thermo replace to an existing system,
an assessment must be made regarding a need for another
CLOSED TANK on the system.
- The upstream pressure of the cooling circuit must be at least
1.5 bar (UNI 10 12 2 point 6.2).
Please refer to UNI 8065-1989 standard (water treatment in
domestic heating systems).