R911172820 | PST 6xxx.115x
Input X23/E13: gun code active = "0"
and X23/E12: program counter
active = 1 (version 3))
0
1
0
1
0
1
0
1
In this version a program start is not possible via input: start 2
(start 2 disables start 1).
With a not permissible gun code the fault message "Parity Fault" is reported.
The inputs: „Tips have been dressed 1" and „acknowledge tip change 1" reset
the actual state of the active gun.
The following inputs / outputs are not used in this version:
X13/E04
X13/E11
X12/E16
X12/E18
X12/E19
X11/A06
X11/A08
X11/A10
Control preferably for suspended station with 2 starts / 2 electrodes and 8
programs.
The electrode assignment is done after memory delete as following:
program 1-4 is assigned to electrode 1,
program 5-8 is assigned to electrode 2.
Program selection with +/- keys, not with program number, see following
table: Program selection version 3. After memory delete both counter stand
on „1".
Tab. 13: Program selection version 3
1 *)
0
1
1 *)
0
X **)
0
1 *)
X **)
0
1 *)
X **)
*)
= Program selection will be interpretied in dependence of the last start
**)
= without meaning
***)
= The actual welding program number will each incremented or decremented for one.
After the next program number come for the gun the lowest number and inverse. Counter
mechanism ...1,2,3,4,1,2,...
The electrode maintenance concept respect the separate inputs and outputs
for electrode number: 1 and electrode number: 2.
Program 4
Pressure contact 2
Tips have been dressed 2
Acknowledge Tip Change 2
Start 2
Tip Dress Request 2
Tip Life Pre-Warning / Life expired 2
End of stepper 2
X **)
X **)
X **)
1
X **)
X **)
X **)
1
X **)
X **)
X **)
1
Bosch Rexroth AG
45/50
Features
1
+1 ***)
1
-1 ***)
2
+1 ***)
2
-1 ***)