Herunterladen Diese Seite drucken

Siemens SITRANS P200 Betriebsanleitung Seite 6

Vorschau ausblenden Andere Handbücher für SITRANS P200:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Technical data
Mode of operation
Measuring range > 1 ... < 60 bar
Input
Measured variable input
Measuring range for gauge pressure
0 ... 1 bar g
0 ... 1.6 bar g
0 ... 2.5 bar g
0 ... 4 bar g
0 ... 6 bar g
0 ... 10 bar g
0 ... 16 bar g
0 ... 25 bar g
0 ... 40 bar g
0 ... 60 bar g
Measuring range for absolute
pressure
0 ... 0,6 bar a
0 ... 1 bar a
0 ... 1.6 bar a
0 ... 2.5 bar a
0 ... 4 bar a
0 ... 6 bar a
0 ... 10 bar a
0 ... 16 bar a
Measuring range for gauge
pressure (for US market only)
0 ... 10 psi g
0 ... 15 psi g
3 ... 15 psi g
0 ... 20 psi g
0 ... 30 psi g
0 ... 60 psi g
0 ... 100 psi g
0 ... 150 psi g
0 ... 200 psi g
0 ... 300 psi g
0 ... 500 psi g
0 ... 750 psi g
0 ... 1 000 psi g
Measuring range for absolute
pressure (for US market only)
0 ... 10 psi a
0 ... 15 psi a
0 ... 20 psi a
0 ... 30 psi a
0 ... 60 psi a
0 ... 100 psi a
0 ... 150 psi a
0 ... 200 psi a
0 ... 300 psi a
Piezoresistive with ceramic diaphragm
Overload limit
Burst pressure
> -0.4 / < 2.5 bar g
> 2.5 bar
> -0.4 / < 4 bar g
> 4 bar
> -0.8 / < 6.25 bar g
> 6.25 bar
> -0.8 / < 10 bar g
> 10 bar
> -1 / < 15 bar g
> 15 bar
> -1 / < 25 bar g
> 25 bar
> -1 / < 40 bar g
> 40 bar
> -1 / < 62.5 bar g
> 62.5 bar
> -1 / < 100 bar g
> 100 bar
> -1 / < 150 bar g
> 150 bar
Overload limit
Burst pressure
> 0 / < 1,5 bar a
2,5 bar a
> 0 / < 2.5 bar a
> 2.5 bar
> 0 / < 4 bar a
> 4 bar
> 0 / < 6.25 bar a
> 6.25 bar
> 0 / < 10 bar a
> 10 bar
> 0 / < 15 bar a
> 15 bar
> 0 / < 25 bar a
> 25 bar
> 0 / < 40 bar a
> 40 bar
Overload limit
Burst pressure
> -5.8 / < 35 psi g
> 35 psi
> -5.8 / < 35 psi g
> 35 psi
> -5.8 / < 35 psi g
> 35 psi
> -5.8 / < 50 psi g
> 50 psi
> -5.8 / < 80 psi g
> 80 psi
> -11.5 / < 140 psi g
> 140 psi
> -14.5 / < 200 psi g
> 200 psi
> -14.5 / < 350 psi g
> 350 psi
> -14.5 / < 550 psi g
> 550 psi
> -14.5 / < 800 psi g
> 800 psi
> -14.5 / < 1 400 psi g
> 1 400 psi
> -14.5 / < 2 000 psi g
> 2 000 psi
> -14.5 / < 2 000 psi g
> 2 000 psi
Overload limit
Burst pressure
> 0 / < 35 psi a
> 35 psi
> 0 / < 35 psi a
> 35 psi
> 0 / < 50 psi a
> 50 psi
> 0 / < 80 psi a
> 80 psi
> 0 / < 140 psi a
> 140 psi
> 0 / < 200 psi a
> 200 psi
> 0 / < 350 psi a
> 350 psi
> 0 / < 550 psi a
> 550 psi
> 0 / < 800 psi a
> 800 psi
Output
Current signal
Burden
Auxiliary power U
B
Current consumption I
B
Voltage signal
Burden
Auxiliary power U
B
Current consumption
Characteristic
Measuring accuracy
Measurement deviation at 25 ÀC (77 ÀF),
Characteristic deviation, hysteresis and
repeatability included
Setting T99
Long-term drift
Start-of-scale value and measuring span
Ambient temperature influence
Start-of-scale value and measuring span
Vibration influence (complying with IEC
60068-2-6)
Auxiliary power influence
Conditions during operation
Ambient conditions
Ambient air temperature
Altitude
Relative humidity
Storage temperature
Degree of protection (complying with
EN 60529)
Electromagnetic compatibility
Construction
Weight
Process connections
Electrical connections
Material of the parts in contact with measured material
Measuring cell
AI
O
- 96 %
2
3
Process connection
stainless steel, material no. 1.4404 (SST 316 L)
Sealing material
Position 15 of
order number
Viton (FPM)
A
Neoprene (CR)
B
Perbunan (NBR)
C
EPDM
D
Material of parts not in contact with the medium
Housing
stainless steel, material no. 1.4404 (SST 316 L)
Pin and socket
plastic
connector housing
CuZn, nickel-plated (plug M12)
Cable
PVC spec.
4 ... 20 mA
(U
- 10 V) / 0.02 A
B
DC 7 ... 33 V
(10 ... 30 V for hazardous areas)
< 20 mA
0 ... 10 VDC
> 10 kΩ
12 ... 33 VDC
< 7 mA at 10 kΩ
Linear rising
typically: 0.25 % of full scale value
maximum: 0.5 % of full scale value
< 0.1 s
0.25 % of full scale value/year
0.25 %/10 K of full-scale value
0.005 %/g to 500 Hz in all
directions
0.005 %/V
Outdoor and indoor use
-25 ⁄ +85 ÀC (-13 ... +185 ÀF)
max. 2 000 m ASL
Use an appropriate power supply for
altitudes higher than 2000 m ASL.
0 ... 100 %
-50 ⁄ +100 ÀC (-58 ... +212 ÀF)
IP65 with plug complying with
EN 175301-803-A
IP67 with M12 plug
IP67 with cable
IP67 with cable fast-fit gland
complying with EN 61326-1
complying with EN 61326-2-3
complying with NAMUR NE21, only
for ATEX device and max. mea-
sured value deviation of < 1 %
approx. 0.090 kg (0.198 lb)
Dimension drawings
Plug complying with EN 175301-
803-A Form A with cable inlet
M16x1.5 or
-14NPT or Pg 11
M12 plug
2- or 3-wire (0.5 mm
2
)
Cable (± 5.4 mm)
Fast-fit cable gland
Media temperature
-15 ... +125 ÀC (+5 ⁄ +257 ÀF)
-35 ... +100 ÀC < 100 bar
(-31 ⁄ +212 ÀF; < 1 450 psi)
-20 ... +100 ÀC (-4 ⁄ +212 ÀF)
-40 ... +145 ÀC < 100 bar
(-40 ⁄ +293 ÀF; < 1 450 psi),
can be used for drinking water
SITRANS P200 (7MF1565)
A5E03304326-02, 12/2011

Werbung

loading

Diese Anleitung auch für:

7mf1565