Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Important! The fitting must be installed, flushed
and tested after the valid norms.
Assembly
1.
Flush through the supply pipes.
2.
Place the mixer including the sealing washer in
position on the sink.
3.
Slip the plastic washer, the slide washer, the
metall washer and collar nut over the hose
and threaded base and tighten the collar nut
by hand. If there is not enough space, please
use only the slide washer and the metall with­
out the plastic washer.
4.
Tighten screws.
5.
Connect the connecting hose / supply pipes
to the angle valves;
cold right ­ hot left.
Large differences in pressure between the hot and
cold water supply should be balanced.

Operation

The mixer is activated by pulling the lever handle.
Turning to the left = cooler water,
turning to the right = warmer water.
Technical Data
Operating pressure:
Recommended operating pressure: 0.1 ­ 0.5 MPa
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0.3 MPa:
Hansgrohe single lever mixers can be used togeth­
er with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0.15 MPa.
To adjust the hot water limiter on single lever mix­
ers, please see page 14.
No adjustment is necessary when using a continu­
ous flow water heater.

English
Spare parts (see page 3)
1.
1.1 screw cover
2.
3.
4.
5.
6.
7.
8.
9.
max. 1 MPa
1.6 MPa
max. 80° C
65° C
13 l/min
llever head
flange
nut
cartridge cpl.
aerator cpl.
fixation cpl.
connection hose 900 mm
spout cpl.
sealing set
38091000
96338000
96468000
96461000
92730000
13913000
95049000
98785000
92830000
92646000

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis