Brief description of the press device

7.1 Automatic press cycle (Fig. 1)
The device features an automatic press cycle. This ensures that the pressing operation is always
completed. For safety reasons, the automatic press cycle only switches on when the pressing
operation has started, i.e. when the fitting starts to be shaped.
After the automatic press cycle has been triggered, the green LED (2) goes out and the pressing
operation runs automatically. The pressing operation can then only be stopped by pressing and
holding the release button (5). After the pressing operation has been completed, the motor
automatically switches off and the green LED (2) lights up again.
If the start button (1) is released before the automatic press cycle begins, the piston in the press
device moves back to its starting position. The pressing operation will not have been completed. The
pressing operation must be triggered again.
7.2 Release button (Fig. 1)
The pressing operation can be stopped at any time by pressing and holding the release button (5).
The piston in the press device then returns to its starting position.
7.3 Slidable finger guard (Fig. 1)
The press device is equipped with a slidable finger guard (6) as the press jaws differ in length. Slide
the finger guard forwards until you hear it click in as soon as you insert shorter press jaws.
7.4 Rotatable head
The press tool is equipped with a rotatable crimping head. The head is rotatable by 180°. Within the
range of these 180° the crimping head can be moved into any position. It is only possible to adjust the
crimping head before the pressing operation. The crimping head cannot be rotated while the pressing
operation is being performed.
7.5 Stroke limit (Fig. 1)
The press device features a stroke limit. When using shorter press jaws the stroke limit helps save
time.
The stroke limit can be switched on and off using an indexing bolt (7) as follows:
Press the start button (1) with the stroke limit being actuated. Immediately:
Pull out the indexing bolt (7) and rotate through 90°.
Allow the indexing bolt (7) to lock into the groove.
Press the start button (1) with the stroke limit being actuated. The indexing bolt can then be pulled out.
7.6 Wireless interface (only ACO203XL BT)(Fig. 1)
The ACO203XL BT device features a wireless interface if it shows the following characteristic:
Blue LED (10)
This wireless interface together with the NovoCheck app can be used to connect the ACO203XL BT to
a mobile terminal device, such as a smartphone, tablet, etc. (Android, IOS; further information at
www.novopress.de). The following functions are available:
Reading the press device
Checking the press device
Making settings
Generating construction site reports.
To establish a connection, the press device must be operational and the NovoCheck app installed on
the terminal device.
The press device can now be connected with the NovoCheck app. (For more information, go to
www.novopress.de) When the connection to the wireless interface was established successfully, the
blue LED (10) lights up.
The blue LED (10) goes out if no connection has been established until the first pressing operation is
performed. A new attempt to establish the connection can only be made if the press device has been
switched off in the meantime. It may be necessary to pull the rechargeable battery for this.
ACO203XL / ACO203XL BT
17
EN