INSTRUCTIONS FOR USE
DRAIN

/ INSTALLATION

3
INSTALLATION
These installation instructions are a guideline only and may vary for each individual
installation.
Observe the following during installation:
Use connectors (coupling sockets, adapters) when connecting to the pipeline.
/
The installation site must be easily accessible at all times for operation and servicing
/
work. For the working place above the backflow stop a minimum height of 35 cm is
provided.
NOTICE Pipeline slope to the drains must be
1.5 % to 2.0 %. The backflow stop has a built-in
gradient, the outflow from the backflow stop
is lower than the inlet.
Align backflow stop horizontally and
Î
vertically, e.g. using a spirit level.
Connect the backflow stop in the direction
Î
of flow (direction of flow is indicated by an
arrow on the cover of the housing and the
casing) to the pipeline.
If not fixed to a wall:
Support backflow stop e.g. with a bracket.
Î
32