SMA Solar Technology AG
12. Remove the AC-RLY assembly from the inverter. When doing so, only hold the assembly by the
handling area (see Section 6.2, page 17).
13. If necessary, replace the AC power controller assembly now (see Section 7, page 18). If
only the AC-RLY assembly is to be replaced, proceed with the installation of the AC-RLY
assembly (see Section 6.2, page 17).
6.2

Installing the AC-RLY Assembly

Figure 2 : Handling area of AC-RLY assembly
Position
Designation
A
Touch only the assembly on the marked areas or on the sheet metal located
underneath the assembly.
Additionally the protected edges of the mounting plate behind the assembly can be used for the
handling.
The remaining areas may not be touched. The assembly can be damaged through touching.
There are sections on this assembly with a safety extra-low voltage circuit (SELV circuit). To ensure
the safety of the circuits, an optical inspection must be carried out before installation.
Replacement Manual
A
A
6 Replacing the AC-RLY Assembly
A
A
STP50-ACRLY-AST-RM-xx-10