Herunterladen Inhalt Inhalt Diese Seite drucken

Waeco COOLMATIC MDC-50 Bedienungsanleitung Seite 35

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
COOLMATIC MDC Series
U
Switch-off voltage of the electronics
OFF
Interior temperature too low in control setting 1
Fault
Compressor runs
constantly
Compressor runs for a
long time
Cooling capacity drops, interior temperature rises
Fault
Compressor runs for a
long time/continuously
Compressor does not
run often
Unusual noises
Fault
Loud humming
Possible cause
Thermostat sensor has no contact to
the vaporiser
Thermostat defective
Short circuit in the thermostat line
A large quantity has been frozen in the
freezer compartment
Possible cause
Vaporiser iced over
Ambient temperature too high
Insufficient ventilation
Condenser is dirty
Fan defective (if installed)
Battery capacity exhausted
Possible cause
A component of the refrigerant circuit
cannot move freely (lies against the
wall)
Foreign body jammed between the
cooling device and the wall
Fan noise (if installed)
Troubleshooting
Remedy
Secure the sensor
Change the thermostat
Remedy
Defrost the vaporiser
Move the cooling device
Clean the condenser
Replace the fan
Charge the battery
Remedy
Bend the component
carefully
Remove the foreign body
35

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis