5. Technical data

Type:
Size
Nominal size
Operating pressure
Gas temperature
Housing material
Protection class
Measured media
Metrological accuracy
class
Table 10 | Technical data

Error limits

Maximum permissible error limits in accordance with EN 12261
±1.0% for Q
to Q
t
max
±2.0% for Q
to Q
min
Fig. 8 | Error limits for TRZ2
Fig. 9 | Error limits for Q

Measuring ranges

73018696f
© Elster GmbH | All rights reserved. Subject to modification
TRZ2
G65 to G1000
DN 65 to DN 150
Max. 100 bar*
Spheroidal graphite cast iron or steel
IP67
Natural gas and various
filtered, non-caustic gases
1.0
* The details on the type label apply depending on the pressure rating.
** Different temperature limits for other measuring ranges (see type label
for actual values)
t
G65 to G1000
DN 65 to DN 150
Max. 100 bar*
-25°C to +70°C**
Natural gas and various
filtered, non-caustic gases
Honeywell
Q
IP67
-