Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Honeywell SM-RI-X Q75 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39

5. Technical data

Type:
Size
Nominal size
Operating pressure
Gas temperature
Housing material
Protection class
Measured media
Metrological accuracy
class
Table 6 | Technical data
Error limits
Maximum permissible error limits in accordance with EN 12261 and OIML
137-1
±1.0% for Q
to Q
t
max
±2.0% for Q
to Q
min
Fig. 9 | Error limits for SM-RI-X
Fig. 10 | Error limits for Q75
73024521a
© Elster GmbH | All rights reserved. Subject to modification
SM-RI-X
G40 to G16000
DN 50 to DN 600
-25°C to +70°C**
Spheroidal graphite cast iron or steel
Natural gas and various filtered, non-caustic gases
1.0
t
G650 to G16000
DN 200 to DN 600
Max. 100 bar*
IP67
* The details on the type label apply depending on the
pressure rating.
** Temperature details for standard version.
Restrictions possible, see type label.
Honeywell
Q75
-10°C to +70°C
-
27

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis