Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 38
Honeywell
Flow disturbances
Minor disturbances
- single manifolds
- twin manifolds
- diffusers
Major disturbances
- pressure regulators
for gas
- other restrictors
Table 7 | Inlet sections

3.6 Installation

CAUTION!
It is essential that you comply with the local health and safety
regulations in force for installing flange connections.
CAUTION!
Fitters for flange connections in countries in which the Pressure
Equipment Directive applies must have an appropriate
qualification (e.g. under EN 1591-4).
CAUTION!
We recommend fitting a cone strainer with a mesh size of 250 μm
to protect the meter. When installing the meter in a vertical
position, with the direction of flow from bottom to top, a strainer
must be fitted to both the meter inlet and outlet (to protect against
falling dirt).
Remove the cone strainer again after around 4 – 6 weeks since it
may be saturated after this time and therefore will inhibit the flow.
22
Typical inlet
sections
Pipe sections installed at a
distance of 2D upstream
of the meter inlet
73018696f
© Elster GmbH | All rights reserved. Subject to modification
TRZ2
L ≥ 2D
No flow conditioner
L ≥ 2D
No flow conditioner
Q
L ≥ 5D
L ≥ 5D
Flow
conditioner
recommended

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Q / q75

Inhaltsverzeichnis