Herunterladen Inhalt Inhalt Diese Seite drucken

Storage; Disposal; Help In Case Of A Malfunction - AL-KO HW 4000 FCS Betriebsanleitung

Vorschau ausblenden Andere Handbücher für HW 4000 FCS:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Maintenance and care
5. Before fitting the filter, check the filter seal
(Fig. C -20) and the housing seal (Fig. C -24)
for damage, and replace if necessary.
6. Fit the filter, screw the filter clear sight cover in
place and tighten hand-tight with the filter key.
Cleaning the check valve
1. Removing and fitting the filter (see Section
"Cleaning the Filter").
2. Unscrew check valve (Fig. C -22) and clean
under flowing water.
3. Replace seal (Fig. C -23) if necessary.
4. Fit check valve.
Unscrew float body
1. Pressure line (Fig. B -13), with elbow nipple
(Fig. B -14), and connecting nipple (Fig. B -16)
.
2. Unscrew screw-in nipple (Fig. D -25) with seal
(Fig. D -26) . Note the fitting position of the
float body (Fig. D -27) . Pull out the float body
and clean it.
3. Replace the float body - note fitting position.
Remove blockages
1. Isolate the unit from the mains and secure
against switching on again.
2. Remove the suction hose from pump inlet.
3. Connect the pressure hose to the water sup-
ply.
4. Allow water to run through the pump housing
until the blockage is removed.

HELP IN CASE OF A MALFUNCTION

CAUTION!
Disconnect the mains plug before any fault rectification work. Faults in the electrical system
must be rectified by an expert electrician.
Malfunction
Pump motor does
not run
Pump not drawing
water
467776_d
Cause
Impeller blocked
Overheating by running dry or water
which is too hot (thermal protection
switch has switched the pump off).
No mains voltage
The suction line is not in the water.
5. Check that the pump is running freely by swit-
ching it on briefly.
6. Start the house water system again as descri-
bed.

STORAGE

If there is a risk of frost, the entire sys-
tem must be drained (pump, lines, sto-
rage vessel and filter chamber).
1. Drain the suction line (Fig. B -18) and the
pressure line (Fig. B -13).
2. Unscrew the drain screw on the filter chamber
(Fig. A -10) and allow the water to flow out of
the pump.
The water in the storage vessel (Fig. A
-6) is pushed out by the air bellows at the
same time.
3. Unscrew the drain screw on the pump cham-
ber (Fig. A -9) and allow the storage vessel
(6) to empty.
4. Screw the drain screws (Fig. A -9, 10) back in
position and store the pump, lines and storage
vessel in a frost-free environment.

DISPOSAL

Do not dispose of worn-out machines
or spent batteries (including recharge-
able batteries) in domestic waste!
The packaging, machine and accessories
are made from recyclable materials and
must be disposed of accordingly.
Rectification
Cleaning the pump.
Release the motor shaft of the impeller
with a screwdriver.
Check the water level on the suction
side. Allow the conveying fluid to cool
down. Repair the pump or replace it.
Check fuses and power supply.
Submerge the end of the suction line
into the water by min. 30 cm.
17

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hw 4500 fcs

Inhaltsverzeichnis