Switching the pump on
see Fig. A
CAUTION!
The immersion pump must not draw in
any solid bodies. Sand and other abra-
sive materials in the conveying medium
will destroy the immersion pump.
1. Unwind the connection cable (2) completely.
2. Make sure that the electrical plug connection
is mounted in the area safe from flooding.
3. Change the terminal position and adjust the
switching points of the float switch (3) indivi-
dually.
4. Attach the cable on the float switch to the
pump housing securely.
Recommended cable length on the float
switch approx. 120 mm
ADVICE
Use a suitable plate to ensure secure
mounting of the immersion pump on
muddy, sandy or stony ground.
5. Immerse the immersion pump in the convey-
ing medium slowly. Hold the immersion pump
at a slight angle to allow any air to esacape.
6. Insert the mains plug into the plug socket.
The immersion pump switches on auto-
matically using the float switch when a
specific water level has been reached,
and switches off again if the water drops
below the switch-off height.
Switching the pump off
1
Remove the mains plug from the plug socket.
Pumping out to residual water level
CAUTION!
Monitor the pump continuously when
pumping out to the residual water level
and avoid the pump running dry. Take the
pump out of service when the residual
water level is reached by pulling out the
mains plug.

HELP IN CASE OF MALFUNCTIONS

CAUTION!
Disconnect the mains plug before any fault rectification work! Faults in the electrical system
must be rectified by a qualified electrician.
12
The float switch must be operated manually to
pump to the residual water level:
1. Remove the mains plug from the plug socket.
2. Lay the float switch up and fix it in position.
3. Insert the mains plug into the plug socket. The
pump switches on and starts to feed.
ADVICE
If the water drops below the residual wa-
ter level, (under 10/40 mm), the pump
will draw air in. In this case, the pump
must be vented when the water level ri-
ses and before using it again.

MAINTENANCE AND CARE

Cleaning the pump
ADVICE
After
conveying
swimming pool water or fluids that leave
a residue, the pump must be flushed out
with clear water.
1. Clean the suction slots on the suction foot if
necessary with clear water.

STORAGE

ADVICE
In the event of a risk of frost, the system
must be drained completely.

DISPOSAL

Do not dispose of worn-out machines
or spent batteries (including recharge-
able batteries) in domestic waste!
The packaging, machine and accessories
are made from recyclable materials and
must be disposed of accordingly.
SUB 6500 / DRAIN 7000 - 7500 / DRAIN 7200
Startup
chlorine-containing

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis