Setting the flush time
You must set the flush time within the first
30 minutes after activating the power
supply.
Prerequisite
Refer to illustration sequence
page 251 while carrying out the
instructions.
1
Restart the urinal flush control. →
See "Restarting the urinal flush
control", page 19.
✓ The urinal flush control restarts.
2
Hold a white sheet of paper in front
of the IR sensor on the bottom edge
of the urinal ceramic appliance for at
least 2 seconds.
✓ 2 short signal tones will sound
after 2 seconds.
3
Remove the white sheet of paper.
4
Hold your hand in front of the IR
sensor within 10  s econds.
5
Remove your hand after the
required number of signal tones.
✓ As soon as you place your hand
in front of the sensor, the flush is
actuated. 1 signal tone
corresponds to a flush volume of
approx. 0.2 l. Example: 12 signal
tones = approx. 2.4 l.
✓ 2 short signal tones confirming
the setting will sound 2 seconds
after you have taken your hand
away.
Result
✓ The flush time is set. The urinal is ready
for operation.
18
Optimising the detection
distance
• If flushes are actuated too soon, too late
or unintentionally, you can optimise the
detection distance of the IR sensor. For
this, you must remeasure the detection
7
,
range.
• You must optimise the detection distance
within the first 30 minutes after activating
the power supply.
Prerequisite
Refer to illustration sequence
page 252 while carrying out the
instructions.
1
2
3
4
5
Result
✓ Once the procedure has been
completed, the flush will be actuated
and the detection distance will be set.
The urinal is ready for operation.
Restart the urinal flush control. →
See "Restarting the urinal flush
control", page 19.
✓ The urinal flush control restarts.
Hold a white sheet of paper in front
of the IR sensor on the bottom edge
of the urinal ceramic appliance.
✓ 2 short signal tones will sound
after 2 seconds.
Keep the white sheet of paper in
front of the IR sensor for a further
15 seconds.
Remove the white sheet as soon as
a signal tone sounds every second.
Step away from the urinal for at least
10 seconds so that the detection
range can be remeasured.
9007202368641931-1 © 07-2018
8
,
966.933 00.0 (02)