Demount the cover for the spray
head.
3
Demount the nozzle.
4
Clean the nozzle and rinse with
water, or replace the nozzle (art. no.
243.333.00.1).
5
Mount the nozzle.
6
Mount the cover for the spray head.
7
Mount the urinal flush control. →
See illustration sequence
page 247.
Result
✓ The urinal is ready for operation.
Replacing the urinal trap
For hygiene reasons, replace the urinal trap
at least once a year.
Prerequisite
Cleaning mode is activated.
Refer to illustration sequence
page 249 while carrying out the
instructions.
1
Demount the cover for the urinal
trap.
2
Demount the urinal trap.
3
Replace the urinal trap (art. no.
243.312.00.1) and the cover for the
urinal trap (art. no. 243.314.00.1).
4
Mount the urinal trap.
5
Mount the cover for the urinal trap.
9007202368641931-1 © 07-2018
966.933 00.0 (02)
Cleaning or replacing the
basket filter
• Clean the basket filter in the solenoid
valve at least every 2 years or if the flush
volume decreases.
• Descale the basket filter with a
commercially available descaling agent if
necessary.
• Replace the basket filter if it can no
longer be completely cleaned and
descaled.
Prerequisite
Refer to illustration sequence
page 250 while carrying out the
3
,
instructions.
1
2
3
4
5
5
,
6
7
8
9
Result
✓ The urinal is ready for operation.
Demount the urinal flush control. →
See illustration sequence
page 246.
Demount the locking bracket.
Demount the coupling.
Remove the basket filter.
Clean, descale or replace the basket
filter.
Install the basket filter.
Mount the coupling and snap in the
solenoid valve.
Mount the locking bracket.
Mount the urinal flush control. →
See illustration sequence
page 247.