Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Operating Instructions SATA filter 500
EN
6. Heat pressure gauge [4-5] with hot air gun to
soften glued bond. Pressure gauge can be unscrewed by hand.
(Caution! Only unscrew pressure gauge by hand)
7. Glue pressure gauge to other side with Loctite 276 and
align the display [4-6] (Caution! Glue is hard after approx. 5 minutes)
8. Screw dummy plug [4-7] to block
9. Fasten wall-mounting kit with 8 screws [4-8]
(Caution! Push filter heads [1-15] together)
10. Fix cover unit with 3 screws [4-9]
(Caution! Note orientation)
11. Insert filter housings [4-10] and mount on the filters
(Caution! Filter housings are only correctly fitted after an audible
"click"!)
12. Slowly open upstream shut-off tap
(not included in delivery)
8.

Use

Risk to life and limb when filter housings have not been fitted correctly!
Only use solvent-resistant, antistatic, undamaged, technically flawless
compressed air hoses with a permanent pressure resistance of mini-
mum 10 bar, e.g. Art. No. 53090!
Notice!
• Mount compressed air connector G¼" (female thread) or suitable
SATA quick coupling G¼" (female thread) (Art. No. 13599, not includ-
ed in delivery) on the ball valve [1-3].
• For regular filter maintenance, replace and activate the SATA filter
timer of the respective filter stage (sintered filters, fine filters and acti-
vated charcoal filters every 6 months).
1. Connect suitable compressed air hose.
2. Turn the regulating cap [1-8] counterclockwise as far as it will go;
state = closed.
3. Fully open the ball valve [1-3].
78
Warning! Attention!

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

520524524l544564584 ... Alle anzeigen

Inhaltsverzeichnis