Global warming potential (GWP):
CO
equivalent:
2
Salt content of water (salt electrolysis):
Pool water temperature increase***:
10 m³
20 m³
0.53°C/h
0.27°C/h
* variable - depends on the ambient conditions.
** single-phase alternating current
*** heat loss was not taken into account (e.g. with or without cover, insulation, etc.)

heatUP 900 technical data

Model:
Item number:
Compressor type:
Total weight (net):
Dimensions (W x H x D):
Heating output*:
Heating input power*:
Heating input current*:
Cooling output*:
Cooling input power*:
Cooling input current*:
Operating voltage and frequency**:
Maximum input current:
Maximum input power:
Coefficient of performance (COP):
Energy efficiency ratio (EER):
Protection class:
IP rating:
Sound power level:
74
675
0.30 kg/t
< 0.5%
(Outside temperature = water temperature =
26°C)
30 m³
40 m³
0.18°C/h
0.13°C/h
heatUP 900
049251
Gree rotary compressor
55 kg
985 mm × 660 mm x 310 mm
9.0 kW
1.5 kW
7.3 A
5.9 kW
1.7 kW
8.2 A
220-240 V~, 50 Hz
9.8 A
2.1 kW
6.0
3.6
I
IPX4
51 dB(A)
50 m³
0.11°C/h