Cooling input current*:
Operating voltage and frequency**:
Maximum input current:
Maximum input power:
Coefficient of performance (COP):
Energy efficiency ratio (EER):
Protection class:
IP rating:
Sound power level:
Heat exchanger material:
Water throughput:
Air throughput:
Nominal suction pressure:
Maximum suction pressure:
Nominal feed pressure:
Maximum feed pressure:
Coolant:
Maximum coolant fill quantity:
Global warming potential (GWP):
CO
equivalent:
2
Salt content of water (salt electrolysis):
Pool water temperature increase***:
10 m³
20 m³
0.90°C/h
0.45°C/h
* variable - depends on the ambient conditions.
** single-phase alternating current
*** heat loss was not taken into account (e.g. with or without cover, insulation, etc.)
76
9.8 A
220-240 V~, 50 Hz
12.0 A
2.6 kW
6.0
3.5
I
IPX4
52 dB(A)
Titanium in PVC
min. 6 m
2,700 m
0.7 MPa
1.5 MPa
3.0 MPa
4.3 MPa
R32
750 g
675
0.51 kg/t
< 0.5%
(Outside temperature = water temperature =
26°C)
30 m³
40 m³
0.30°C/h
0.22°C/h
/h
3
/h
3
50 m³
0.18°C/h