Problem
Display: error message P1
Display: error message P3
Display: error message P5
Display: error message P6
If the problem persists, contact the customer service listed on the last page.

Technical data

Model:
Item number:
Total weight (net/gross):
Dimensions (W x H x D):
Heating output *:
Heating input power *:
Input power rating:
Heating input current *:
Operating voltage and frequency **:
Coefficient of performance (COP):
Protection class:
Protection type:
Sound power level:
Heat exchanger material:
Possible cause
The temperature sensor at
the inlet is defective or
does not emit a signal.
The temperature sensor at
the heat exchanger is
defective or does not emit
a signal.
Pressure in refrigerant
circuit is too low.
Insufficient water flow.
BP-39WS-B Mini
049275
19 kg / 21 kg
365 mm × 370 mm x 320 mm
3.9kW
0.65kW
0.85kW
3.3A
220 – 240 V~, 50 Hz
6.0
I
IPX4
47 dB(A)
Titanium in PVC
Remedy
Contact an authorized qualified
person.
Contact an authorized qualified
person.
Contact an authorized qualified
person.
Increase the water throughput of
the hydraulic circuit that supplies
the heat pump.
Contact an authorized qualified
person.