When the cause of the alarm has been
removed, the normal operation of the
equipment is restored.

8.1.3.12 Error messages

Pr1
Error in probe in upper part of the boiler
Solutions:
- Check that the type of probe is in
conformity with parameter P0 settings;
- Check the probe is intact;
- Check the equipment-probe connection;
- Check the temperature of the upper part of
the boiler.
Main consequences:
- The equipment stops working.
Pr2
Error in probe in lower part of the boiler
Solutions:
- The same as the previous situation but
relating to the probe in the lower part of the
boiler.
Main consequences:
- The equipment stops working.
Pr3
Error in evaporator probe
Solutions:
- The same as the previous situation but
relating to the evaporator probe.
- The equipment stops working.
When the cause of the alarm has been
removed, the normal operation of the
equipment is restored.
8.1.3.13 Defrosting
Defrosting can be enabled in the following way:
Automatically, when the temperature of the
evaporator is below that established in parameter
d17 (only if P4 has a value other than 0);
In any case, between one defrosting procedure and
another, the compressor must have been left switched
on for a period either longer than or equal to d18
minutes. Otherwise the request to enable the defrosting
procedure will not be accepted.
If P4 = 1, d2 represents the temperature of the
evaporator, above which the defrosting procedure is
terminated. Vice versa, if P4 = 0 or P4 = 2, parameter
d2 is not taken into consideration.
If during the defrosting procedure the evaporate or
probe is above the threshold set by means of
parameters d2 and P4 = 1, the request to enable the
defrosting procedure is not accepted.
Page 28
The defrosting procedure consists of three stages:
Defrosting stage: Parameter d3 establishes the
maximum duration of the stage.
Output status:
The compressor is active if d1 = 1,otherwise it is
switched off;
The defrosting relay is active if d1 = 0 or d1 =
1,otherwise it is switched off;
The fans are switched on if d1 = 2, otherwise they
are switched off.
Dripping stage: Parameter d7 establishes the
duration of the stage.
Output status:
The compressor is switched off;
-
The defrosting relay is active if d1 = 0 or d1 =
-
1,otherwise it is switched off;
The fans are switched off.
-
Drying stage.
Parameter d16 establishes the duration of the
stage. Output status:
The compressor acts according to parameter d8;
The defrosting relay is active if d1 = 0 or d1 =
-
1,otherwise it is switched off;
The fans are switched off.
-
If the "Anti-Legionella" or the "Overboost"
functions are in progress, the defrosting
procedure will not be enabled.
8.1.3.14 Day and real time settings
Make sure that the keyboard is not locked
(paragraph 8.1.3.3) and that no other advanced
procedure is in progress;
Press and release the
key: the display will
show the first code available;
Press and release either the
until "rtc" is shown;
The day is displayed as 1...7 (number 1 corresponding
to Monday).
To change the day of the week:
Press and release the
key: the display will
show "dd" followed by the two numbers
representing the day;
Press and release either the
within 15 seconds.
To change the time:
Press and release the
key while changing the
day of the month: the display will show "hh"
followed by the two numbers representing the time
(Time is shown in the 24 hr. format);
Press and release either the
within 15 seconds.
Installation and user manual
or the
key
or the
key
or the
key