8.1.3 Basic management

8.1.3.1 Manual switching on /off of the
equipment
Keep the
key pressed for 1 second: the
on/stand-by LED will switch off/on.
The equipment can be switched on/off also in
certain timeslots; the parameters HOn and HOF
can be seen (paragraph 8.1.3.6).
Manual switching on/off always has the priority
over the timeslot operating mode.
If the keyboard has been locked (paragraph
8.1.3.3) or an advanced procedure is in
progress, it will not be possible to carry out the
normal switching on/off of the equipment.
Every time the equipment is switched on, a
series of internal inspections are carried out
before the heat pump is enabled. Such
condition is reported by means of the flashing
of the compressor indicator light
verification period has passed (approx. 5
minutes) the indicator light remains lit and this
indicates that the unit is switched on.

8.1.3.2 Change of operating mode

(AUTOMATIC, ECONOMY
and OVERBOOST)
8.1.3.2.1
AUTOMATIC operating mode
To manually start the AUTOMATIC mode, carry out the
following procedure:
Make sure that the keyboard is not locked
(paragraph 8.1.3.3) and that no other advanced
procedure is in progress
;
Press per the
key for 1 second, "Auto" starts
to flash;
Press the
key again to confirm and start the
AUTOMATIC operating mode.
To exit the procedure:
Press the
key to exit this procedure without
changing the mode.
8.1.3.2.2
ECO (economy) operating mode
To manually start the ECO operating mode, carry out
the following procedure:
Make sure that the keyboard is not locked
(paragraph 8.1.3.3), that no other advanced
procedure is in progress and that the equipment
is not in the Overboost operating mode;
Installation and user manual
Press the
flash;
Press the
ECONOMY operating mode.
To exit the procedure:
Press the
changing the mode.
8.1.3.2.3
OVERBOOST operating mode
To manually start the OVERBOOST operating mode,
carry out the following procedure:
Make sure that the keyboard is not locked
(paragraph 8.1.3.3) and that no other advanced
procedure is in progress;
Press the
"Auto" starts to flash;
Press the
the display;
Press the
OVERBOOST operating mode.
To exit the procedure:
Press the
changing the mode.
. Once the
8.1.3.3 Keyboard locking/unlocking
To lock the keyboard, carry out the following procedure:
Make sure that no other advanced procedure is in
progress;
Keep the
1 second: "Loc" will be shown on the display for
1 second.
If the keyboard is locked, it will not be possible to carry
out any kind of operation on the display interface.
By pressing any key, "Loc" will be shown
for 1 second on the display.
To unlock the keyboard:
Keep the
1 second: "UnL" will be shown for 1 second
on the display.
8.1.3.4 Temperature setting in the ECO
operating mode (SP1)
Make sure that the keyboard is not locked
(paragraph 8.1.3.3) and that no other advanced
procedure is in progress
Press and release the
shown on the display;
Press and release the
LED
will flash;
Press either the
seconds; parameters r3, r4 and r5 can be seen;
key for 1 second, "ECO" starts to
key again to confirm and start the
key to exit this procedure without
key for 1 second, either "ECO" or
or
keys until "ObSt" flashes on
key again to confirm and start the
key to exit this procedure without
and the
keys pressed for
and the
keys pressed for
;
key: "SP1" will be
key: the compressor
or the
key within 15