Beurer medical BM 75 Gebrauchsanweisung Seite 18

Vorschau ausblenden Andere Handbücher für BM 75:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Direct current
Disposal in accordance with EC Directive
WEEE (Waste Electrical and Electronic
Equipment)
Manufacturer
Permissible transport and storage tem-
Storage
perature. Permissible transport and storage
60°C
humidity.
-10°C
RH 10-90%
Operating
Permissible operating temperature and
40°C
humidity
10°C
RH 15%-85%
Protected against foreign objects equal to
IP 21
or greater than 12.5 mm in diameter and
against vertically falling drops of water
SN
Serial number
The CE labelling certifies that the product
complies with the essential requirements of
0483
Directive 93/42/EEC on medical products.
Advice on use
• In order to ensure comparable values, always measure your
blood pressure at the same time of day.
• Before every measurement, relax for about five minutes.
• If you want to perform several measurements on the same
person, wait five minutes between each measurement.
• Do not take a measurement within 30 minutes after eating,
drinking, smoking or exercising.
Downloaded from
www.Manualslib.com
manuals search engine
• Repeat the measurement if you are unsure of the measured
value.
• The measurements taken by you are for your information
only – they are not a substitute for a medical examination!
Discuss the measurements with your doctor, and never base
any medical decisions on them (e.g. medicines and their
administration)!
• Do not use the blood pressure monitor on newborns or pati-
ents with preeclampsia. We recommend consulting a doctor
before using the blood pressure monitor during pregnancy.
• Cardiovascular diseases may lead to incorrect measure-
ments or have a detrimental effect on measurement ac-
curacy. The same also applies to very low blood pressure,
diabetes, circulatory disorders and arrhythmias as well as
chills or shaking.
• The blood pressure monitor must not be used in connection
with a high-frequency surgical unit.
• Only use the device on people who have the specified upper
arm measurement for the device.
• Please note that when inflating, the functions of the limb in
question may be impaired.
• During the blood pressure measurement, blood circulation
must not be stopped for an unnecessarily long time. If the
device malfunctions, remove the cuff from the arm.
• Avoid any mechanical restriction, compression or bending of
the cuff line.
• Do not allow sustained pressure in the cuff or frequent meas-
urements. The resulting restriction of the blood flow may
cause injury.