Herunterladen Inhalt Inhalt Diese Seite drucken

Programming The Temperature Mode "O - ECM Manufacture TECHNIKA V Profi PID Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

We recommend a temperature setting on the PID of 124°C at about 1.25 bar, which corresponds to an outlet
temperature of about 94°C (121°F). If the temperature is set lower, there will not be enough pressure to foam
milk
Please note that after changing the steam temperature on the display, it takes a certain
amount of time for the corresponding temperature to be reached on the brewing group.
To adjust the temperature please follow the instructions below:
1
Switch the machine on in order to activate the boiler. The temperature
of the boiler is of no importance in programming. The heater is
inactive during programming.
+
at the same time until 't1' (boiler) appears on the
2
Press
and
display,
+
in order to progress to the submenu of 't1' and to change the
3
Press
temperature value. The nominal temperature value is displayed.
4
Quickly press
to decrease
+
to increase
the temperature value.
5
Please wait a short while after having set the temperature ;
until 't1' is displayed.
6
Press
to leave the programming mode.

Programming the Temperature Mode "o"

6.3.2
You can also set whether the temperature value of "t1" should be displayed in °C or °F.
To adjust this setting, proceed as follows:
+
at the same time and "t1" will appear on the display.
1 Press
and
2
Press the button
+
Press
to enter the menu.
3 Now you can choose between C for Celsius and F for Fahrenheit by
pressing
. This will also set t2.
4 Wait a short time and you will exit the menu automatically.
Translation of the original German user manual
twice. After t1, "o" appears on the display.
ENGLISH
28

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

85285

Inhaltsverzeichnis