1
Important: In order to get the best result when frothing milk, open the steam valve by activating the
steam lever for approx. 5 seconds to release the condensation water in the steam wand.
2
Immerse the steam nozzle (at the end of the steam dispenser) in the liquid.
3
Re-open the steam valve.
4
Heat and/or froth the liquid.
5
After frothing or heating, release the steam into the drip tray to keep the holes of the steam nozzle clean.
Risk of injury
Always keep the steam nozzle underneath the surface of the liquid while heating or frothing
in order to avoid being sprayed.
Important
After every application clean the steam nozzle and the steam dispenser with a non-abrasive,
damp cloth; to remove possible liquid residues.
Risk of injury
Avoid skin contact with the steam dispenser while cleaning!
7

CLEANING AND MAINTENANCE

Regular and thorough care is very important for the performance, the longevity and the safety of your
machine.
Caution!
Always switch off the machine (power switch in lower position), disconnect the power cord
and let the machine cool down to room temperature (for at least 30 minutes) before cleaning.
Never submerse the machine in water.There is a risk of electric shock

7.1 General cleaning

Daily cleaning:
Portafilter, filters, water tank, drip tray, drip plate of the drip tray, measuring-spoon and tamper require daily
cleaning. Clean with warm water and/or with a food safe detergent.
Please note that portafilters, drip tray and water tank are not suitable for the dishwasher.
Clean the shower screen and the group gasket in the lower part of the group and remove visible deposits
without dissasembling the parts.
Cleaning as necessary:
Clean the steam and hot water valve after every use.
Clean the body when the machine is switched off and cold.
Depending on usage, please refresh the boiler water every 1 - 2 weeks by operating the pump switch and
extracting hot water from the hot water wand.
Use a soft, damp cloth for cleaning.
Never use abrasive or chloric detergents!
Empty the water drip tray regularly and do not wait until it is full.

7.2 Brew group cleaning

A ECM brew group cleaner is available at your specialised dealer. With this detergent, you can clean and
degrease the group very easily. The cleaning is carried out using the blind filter included in delivery. The
group cleaning can be carried out after approx. 90 - 150 cups.
Follow the instructions as noted below:
1
Heat up the machine.
2
Place the blind filter into the portafilter.
3
Put approx. 3 - 5g of the group cleaning powder into the blind filter.