Display:
I
14
- The display
shows the selected parameter (A, C, 1-8).
14
Available parameters:
The heat pump has two temperature sensors that measure the following temperatures:
Parameters
A
current water temperature at inlet
C
current temperature at heat exchanger
The heat pump has eight adjustable parameters:
Parameters
1
desired water temperature
2
Temperature difference for restart
3
Outlet temperature protection
4
Automatic restart
5
Duration for automatic defrost function
6
Temperature setting for automatic defrost
function
7
Temperature setting for exiting automatic
defrosting
8
Exit automatic defrosting
54
16
Set
18
17
Display range
-19 °C to +99 °C
-19 °C to +99 °C
Setting range
10 min to 90 min
10 min to 40 min
Default
15 °C to 35 °C
1 °C to 10 °C
30 °C to 80 °C
0 - 1
-30 °C to 0 °C
1 °C to 30 °C
-
-
27°C
2°C
47°C
1
40min
0°C
2°C
30min