HOOD WITH INTERNAL RECIRCULATION (FILTERING)
In this version, air passes through zeolite-carbon filters and the
E.ION ionising system to be purified and recycled in the envi-
ronment. Make sure the zeolite-carbon filters are installed in
the hood, otherwise, apply them as indicated in the assembly
instructions.
ASSEMBLY INSTRUCTIONS
only intended for personnel qualified
The hood can be installed in various configurations.
The generic assembly steps apply to all installations; for each case,
follow the specific steps provided for the required installation.

OPERATION

WHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to direct fumes
and vapours towards the suction surface.
After cooking, leave the hood operating until complete extraction of all vapours
and odours. By means of the Timer function, it is possible to set auto switch-off
function which will allow the hood to turn off automatically after 15 minutes of
operation.
AIR QUALITY
Air quality is displayed by the colour of the leaf.
Green = excellent quality.
Yellow = pollutant agents found.
The higher the number of pollutant agents, the darker
the yellow
colour.
WHICH SPEED IS TO BE SELECTED?
1st speed: maintains the circulation of clean air with low electricity consumption.
2nd speed: normal conditions of use.
3rd speed: presence of strong odours and vapours.
4th speed: rapid disposal of odours and vapours.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The zeolite-carbon filters must be reactivated every 18 months and replaced
every 3 years. For further details see the "MAINTENANCE" chap.
TOUCH PUSHBUTTON PANEL
Motor ON/OFF
Upon start-up, the speed is that stored at the previous operation.
Increase speed from 1 to 4
Speed 4 is only active for a few
minutes, then speed 3 activa-
tes.
Riduzione velocità da 4 a 1
Automatic cycle: the hood only activates when pollutant agen-
ts are found.
The function deactivates if:
- no pollutant agents are found for 3 hours;
- The TIMER key ( ) is pressed again.;
- keys + and - are pressed
TIMER (red LED flashing)
Auto switch-off after 15 min.
The function deactivates (red LED off ) if:
- The TIMER key ( ) is pressed again.
- The ON/OFF key ( ) is pressed.
The speeds are indicated by the
LEDs on the keys:
Speed 1
Speed 2
Speed 3
Speed 4
("+" LED flashing)
USING THE RADIO CONTROL Code 105080058
WARNINGS!:
Place the hood away from sources of electromagnetic waves (e.g.
microwave ovens), which could interfere with the radio control
and with the hood electronics.
The maximum operating distance is 5 metres, that may vary according to
the presence of electromagnetic interferences.
Radio control operated at 433.92MHz.
DESCRIPTION OF TRANSMITTING COMMANDS
ATTENTION!
pair radio control 105080058 on the hood and on the ionizing filter
KIT
KIT
code
105080058
TX
RADIO CONTROL CODE CHANGE
With only one radio control, go directly to point 2.
With several radio controls in the same room, a new code can be created by
following the procedure below.
Disconnect the power to the hood before starting the procedure.
1) - CREATE A NEW CODE
The procedure is to be carried out on the radio control.
• Press LIGHT
and TIMER
• Press DOWN
on the radio control: saving is confirmed by three brief flash-
es of the display. The new code cancels and replaces the previous default
code.
Reconnect the hood to the electrical power supply, making sure
that the lights and motor are
2) - ASSOCIATING THE RADIO CONTROL WITH THE HOOD
USING THE ELECTRONIC PUSHBUTTON PANEL
) on the hood pushbutton panel for 2 seconds:
press TIMER (
the red LED lights up.
press any key on the radio control within 10 seconds.
19
UP
Motor switch-on and speed increase
from 1 to 4. Speed 4 is only active for
a few minutes.
DOWN
Speed decrease and motor switch-off.
with Motor off: function
ON
Light ON-OFF
Short impulse:
turn light on and off
Long impulse (for hoods with dim-
mable light):
With the light on, press and hold down
the button to adjust the light intensity.
Once the desired light intensity has
been reached, release the button.
TIMER ON: The motor automatically
switches off after 15 min.
The function is automatically disabled
if the motor is switched off (
Command transmission active
Hood
simultaneously until the display starts flashing.
off.
key)