Herunterladen Inhalt Inhalt Diese Seite drucken

Brusa NLG41x Betriebsanleitung Seite 35

Nlg4 serie
Inhaltsverzeichnis

Werbung

with the following meanings:
Status:
Operation or error status of the NLG4 (status 0 = O.K.)
decimal number, which consists (additive) of:
> malfunction
> error overvoltage mains
> error overvoltage battery
> error connection battery temp sensor #1
> error connection battery temp sensor #2
> error over-temperature battery
> error maximum energy overflow
> error maximum charge overflow
> error maximum time overflow
> error no maintenance charge was done
> error overtemperature at init. charge
> error timeout after init. or maint. Charge
> error precharge was notr successful
> error safety timeout for main-charge section
> error safety temp-rise in main -charge section
> error safety timeout for over-charge section
Section :
section of the charging profile
lmains
:
current from mains
lbatt
:
current to battery
Um_pk :
voltage mains peak value
Umeff
:
voltage mains effective value
Ubatt
:
voltage of the battery
Tpstg
:
temperature of the power stage
Tbatl
:
temperature of the first battery temp. sensor
Tbat2
:
temperature of the second battery temp. sensor
Tbatt
:
maximum temperature of the battery temp. sensors
power
:
value of the power-limitation in percent
Pprim
:
primary (input) power
*
1
*
2
*
4
*
8
*
16
*
32
*
64
*
128
*
256
*
512
*
1024
*
2048
*
4096
*
8192
*
16384
*
32768
Seite 2

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Nlg42xNlg43xNlg42xwNlg43xw

Inhaltsverzeichnis