7. Technical data (summary)
Data
Nom. battery voltage
Nom. power
Max. mains current
Current phase angle
Distortion factor
Efficiency
Weight
Air-cooled
version
Insulation standard
Operating temp. range
Reduced output
Water-cooled
version
Insulation standard
Operating temp. range
Reduced output
NLG4
Description
U
Bnom
P
in
I
N max
cos phi
√ Σ (i
2
)
/ i
2n+1
eff
η
m
T
a
T
a
T
a
T
a
Value
Condition
72 . . 372 V
see list of types
3.6 kW
U
16 A
U
0.98
I
<0.03
I
0.92
NLG412
U
P
7.3 kg
incl. supply cord
IP54
-25°..+70 °C
free-standing
above 30 °C
ambient temperature
IP65
-25°..+80 °C
above 50 °C
coolant temp. (intake)
= 230 V
mains
eff
= 230 V
mains
eff
= 16 A
N
= 16 A
N
= 200 V
B
= 3.6 kW
in
19

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Nlg42xNlg43xNlg42xwNlg43xw