Herunterladen Inhalt Inhalt Diese Seite drucken

Wiring Diagram - IARP GRANDLUX 200 Gebrauchs- Und Bedienungs Anleitungen

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 43
LIGHTING DEVICE WITH TANK'S LAMPS
Lighting and appliance electrical supply lines must be
separate and indipendent.
Each line must be protected by a very sensitive dif-
ferential magnetothermal switch (IGMD) (In=16A,
Id=30mA) and linked to the general earthing plant.
Absolutely never use reduction units, patch cords,
adapters or multiple socket outlets to connect the appliances.
DIRECTLY connect the equipment to the mains.
IGMD) Magnetothermal differential main switch of lighting supply line.
IL)
Lamps switch (on the appliance)
LPS)
Electronic Ballast
LDV)
Tank lamp
Example of connection:
Model: GRAND LUX 200
80%Rated current of Magnetothermal Differential Main Switch (IG) ......................... 12.8 A
Rated current absorbed by each lighting plant ................................................................ 0.05A
GRAND LUX 150-200
IGMD
1) Appliance cable
2) Lighting cable
3) Electronic Ballast box

WIRING DIAGRAM