Table  1.4:  Mounting  Zone  Load  Ratings  for  Performance  Modules 
(Pending IEC Certification) 
Distance 
Applicable 
Mounting 
2
Products
 
Zone  
corner 
183‐283 
466‐566 
783‐ 833 
300‐400 
P3 UPP 
465‐565 
(2066 x 1160 x 
 
35mm)
Frame 
2
Holes
 
P5 UPP 
540‐640 
(2384 x 1092 x 
 
35mm)
2 Refer to Table 2 for different mounting hole locations 
3 Safety Factor 1.5 included 
4 IEC validated 
 
5.3 Bifacial Gain 
Various  environmental  and  installation  parameters  affect  bifacial 
gain. Albedo is a measure of the amount of light reflected from the 
ground surface. A higher albedo factor will increase irradiance on the 
backside and result in higher bifacial gain of the module. The surface 
conditions, month of the year, time of day, GHI and DNI both influence 
the amount of incident rearside irradiance. 
  
Maxeon recommends to check with solar module mounting hardware 
supplier  in  order  to  determine  the  Structure  Shading  factor  of  your 
particular  installation.  The  Structure  Shading  Factor  varies  with 
racking  system  design,  irradiance,  albedo  and  height  of  module 
installation above ground and has an overall impact on the rear side 
irradiance mismatch. 
  
The Rearside mismatch losses are proportional to the albedo, height 
of  the  modules  above  ground  and  structure  shading  factor.  The 
irradiance  non‐uniformity  on  the  rearside  results  in  mismatch 
generally  as  the  albedo  increases  and  installation  height  of  the 
modules are lower to the ground. 
 
5.4 Bifacial Electrical Considerations 
The overall electrical bifacial gain is determined by the combination of 
albedo,  irradiance,  shading  losses  from  the  rearside,  rearside 
mismatch and height of installation above ground. Please refer to the 
Maxeon  datasheet  for  the  electrical  outputs  with  respect  to  the 
overall  bifacial  gain.  Please  utilise  a  suitable  performance  software 
package to simulate the overall bifacial gain. 
 
 
 
 
© January 2021 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice. 
Wind (up & 
from 
down) / 
Mounting 
Snow(down) 
Method 
3
(mm) 
(units in Pa)
 
1600/2400 
4
1600/3600
 
Clamp 
1600/1600 
1600/1600 
1600/2400 
383 
1600/1600 
504 
1600/3600 
683 
1600/1600 
833 
1600/3600 
Clamp 
Safety and Installation Instructions ‐ Document 001‐15497 Rev U
5.5 Handling of Modules during Installation 
Do  not  place  modules  face  forward  in  direct  contact  with  abrasive 
surfaces like roofs, driveways, wooden pallets, railings, stucco walls, 
etc... 
The  module  front  surface  glass  is  sensitive  to  oils  and  abrasive 
surfaces, which may lead to scratches and irregular soiling. 
During storage, modules need to be protected from rain or any kinds 
of liquids. Required storage temperature is between 10°C to 40°C in a 
dry environment (humidity between 30 to 80%). Do not store modules 
outdoor to avoid moisture and wet conditions. 
 
Modules that feature antireflective coated glass are prone to visible 
finger  print  marks  if  touched  on  the  front  glass  surface.  Maxeon 
 
recommends handing modules with anti‐reflective glass with gloves 
(no leather gloves) or limiting touching of the front surface.  Any finger 
print  marks  resulting  from  installation  will  naturally  disappear  over 
time or can be reduced by following the washing guidelines in Section 
6.0  below.  Any  module  coverage  (colored  plastic  tarps  or  similar) 
during installation can lead to permanent front glass discoloration and 
is  not  recommended.  The  use  of  vacuum  lifting  pads  can  cause 
permanent marks on the front glass. Never lift or move the module 
using the cables or the junction box under any‐circumstances. 
 
Shading  incidence  need  to  be  avoided  during  PV  system  operation. 
The  system  is  not  supposed  to  be  energized  until  the  mounting 
scaffolding, fences or railing have been removed from the roof. 
Systems should be disconnected in any cases of maintenance which 
Bolt 
can  cause  shading  (e.g.  chimney  sweeping,  any  roof  maintenance, 
antenna/dish installations, etc). 
6.0 Maintenance  
Maxeon  recommends  visual  inspection  on  a  regular  basis  of  all 
modules  for  safe  electrical  connections,  sound  mechanical 
connection, and freedom from corrosion. This visual inspection should 
be performed by trained personnel. The standard frequency is once a 
year  according  to  environmental  conditions  Periodic  cleaning  of 
modules is recommended but is not required.  Periodic cleaning has 
resulted  in  improved  performance  levels,  especially  in  regions  with 
low levels of annual precipitation (less than 46,3cm (18,25  inches)). 
Consult  your  dealer  or  supplier  about  recommended  cleaning 
schedules for your area. 
 
To clean a module, wash with  potable, non‐heated, water.  Normal 
water pressure is more than adequate, but pressurized water up to 
100  bar  (min.50  cm  distance)  may  be  used.  Maxeon  recommends 
using  a  large  hosepipe  and  not  to  perform  cleaning  at  high  outside 
temperatures.  Fingerprints,  stains,  or  accumulations  of  dirt  on  the 
front surface may be removed as follows: first rinse off area and let 
soak for a short period of time (5 mins). Re‐wet and use a soft sponge 
or seamless cloth to wipe glass surface in a circular motion.  
Fingerprints typically can be removed with a soft cloth or sponge and 
water  after  wetting.  Do  not  use  harsh  cleaning  materials  such  as 
scouring  powder,  steel  wool,  scrapers,  blades,  or  other  sharp 
instruments  to  clean  the  glass  surface  of  the  module.  Use  of  such 
materials or cleaning without consultation will invalidate the product 
warranty. As dry cleaning is also risky for Anti‐Reflective (AR) coated 
module  surface,  spinning  brush  is  not  recommended  for  module 
cleaning. 
 
 
 
 
 
 
 
 