For 96 cells, P‐Series and 104c:
For 128 cells,P‐Series and MAX5 Commercial:
Table 1: Approved module clamping/direct fixation zones
Mounting zone distance from
Module Configuration
Frame
Module size
type
(1&2&3&4)
G3
(Black)
96 cells, 104
Silver &
50‐350
cells (MAX2
G4.1 &
and MAX3), P3
G4.2 &
BLK and P3
G4.3
RES+
G4 &
128 cells and
G4.1 &
50‐350
P19‐COM
G4.2
G4.2 &
P3‐COM
50‐350
G4.3
MAX5‐COM
G4.2
50‐350
D ‐ There is a 20mm zone at 388‐408mm from the corner where mounting is not
allowed due to the module stacking pin feature. Not applicable for all P19 Series, all P3
Series, 96 cells residential modules, all 104 cells and MAX5 modules.
1) No part of the module clamp may extend beyond this area.
Figure 3: Mounting Configurations
Configurations 1 and 2 show mounting with rail support, 3 and 4
show mounting without rail support. In "With Rail Support" the rails
becomes conventional or rails transverse while "Without Rail
Support" becomes end mounted in long or short side. In the case
when the glass deflects it would not deflect in the rails for additional
support.
© January 2021 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice.
Frame
1
corner in (mm)
holes
A
B
C
(1&2&3&4)
(1&2&3&4)
(1&2&3&4)
150‐380
50‐150
Drawing in
the Table 2
408‐880
50‐375
408‐833
50‐375
296‐796
50‐296
Safety and Installation Instructions ‐ Document 001‐15497 Rev U
Table 1.2: Mounting Zone Design Load Ratings for Racking system
without rail support underneath the module. Refer to configuration 3
and 4 in Fig.3
Module
Configuration
Module
Frame
size
Black &
96 cells,
Silver &
104 cells
G4.1 &
(MAX2 and
G4.2 &
MAX3) and
P3 BLK
P3 RES+
(****)
G4 &
128 cells,
G4.1 &
P19‐COM
G4.2 &
P3‐COM
MAX5‐
COM
(*): 5400Pa is allowed with clamps and mounting rails along the longer side of the frame
(**): 2400/2400Pa are allowed with clamps and mounting rails along the longer side of
the frame
For Rooftop application 1200/1200Pa is allowed with only clamps
(***) Safety factor of 1.5 included
(****) Not IEC validated
E
Table 1.3: Mounting Zone Load Ratings for Racking system with rail
support. Refer to Configuration 1 and 2 in Fig.3
Module Configuration
Module size
96 cells, 104 cells
As per
(MAX2 and MAX3)and
P3 BLK
P3 RES+
128 cells and P19‐COM
P3‐COM
MAX5‐COM
Figure 4: Mounting Zone Locations for Performance modules
For P3 and P5 UPP:
MAXEON SOLAR TECHNOLOGIES, LTD.
Wind (up & down) / Snow (down)
(units in Pa) (***)
End
Frame
Mount
Holes
B
type
A
E
(1&2&3&4)
(1&2&3&4)
(1&2&3&4)
G3
2400/
2400/
2400/
(*)
2400
5400
5400
G4.3
1300/
1600/
1600/
G4.3
1600
2400
2400
Not
2400/
3600/
applicable
5400
3600
(**)
G4.2
1600/
1600/
1600/
G4.3
1600
2400
2400
Not
2400/
3600/
applicable
G4.2
5400
3600
(**)
Frame type
G3 (Black &Silver) &
G4.1 & G4.2
G4.3
G4 & G4.1 & G4.2
G4.2 & G4.3
G4.2
C
(1&2&3&4)
or B + C
(B
+C
or
B
+C
)
1&3
2&4
2&4
1&3
Or A + B
(A
+B
or
A
+B
)
1&3
2&4
2&4
1&3
Or A + C
(A
+C
or
A
+C
)
1&3
2&4
2&4
1&3
2400/2400
1300/
1600
2400/2400
1600/1600
1600/1600
Wind (up & down) /
Snow (down)
(units in Pa) (***)
B
C
(1&2&3&4)
(1&2&3&4)
2400 / 5400 2400 / 2400
1600/3600
1600/3600
3600 / 5400 2400/ 3600
2000/2400
1600/2400
3600/3600
2800/2800