5.1.4 Exempt appliances

Exempt appliances are appliances (ovens, wood burners and stoves) which have been exempted under the Clean
Air Act 1993 or Clean Air (Northern Ireland) Order 1981.
Appliances which are exempt for use in Smoke Control Areas: https://smokecontrol.defra.gov.uk/appliances.php

5.1.5 Outside air connection

Some fires can be provided with an outside air connection. For an optimum operation of the appliance, the
following should be taken into account in case of an outside air connection:
• The passage of the outside air connection and possibly the passage of a grate may not be smaller than the
passage of the outside air connection on the fire.
• Make sure the maximum underpressure created in the combustion air supply pipe is 4 pascal. If a higher
underpressure is created, the fire will not function properly and (hot) flue gases may flow back into the supply
pipe.
• Prevent placing the outside air supply in an underpressure area on the outside of the house. If possible, place a
supply pipe with T piece to 2 sides of the house.
• The combustion air supply pipe may not be placed higher than the bottom of the fire. This will prevent flue gases
from flowing back.
• The combustion air pipe that is connected to the fire should be made of non combustible material.
• The fire will function properly with a flexible pipe with a maximum length of 11 metres and 4 bends. In case of a
longer pipe or more bends, we recommend placing a pipe with a larger diameter (100-125mm).
• If a crawl space is properly aerated with open grates, it is allowed to retrieve combustion air from there. If there is
no proper aeration in the crawl space, it is possible that harmful radon gases are drawn in. This is not allowed
according to national regulations.
Further information on the outside air connection, if applicable, can be found in section 9 'Appliance specific
information'.
Please note that HETAS product approval remains valid for the appliance only when installed with its air supply
taken from the room of installation and the room is ventilated permanently to outside air as necessary in
accordance with the guidelines given in Approved Document J. HETAS product approval is not valid for
appliances fitted with an external air supply ducted directly to the appliance.

5.2 HETAS amendments

For supplementary information for the verification of Ecodesign Compliance under the HETAS product approval
scheme see appendix 3 if applicable.
Health and safety precautions
Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work
Act are met.
Handling
Adequate facilities must be available for loading, unloading and site handling.
Fire Cement
Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of
contact wash immediately with plenty of water.
Asbestos
This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of installation then
please seek specialist guidance and use appropriate protective equipment.
Metal Parts
When installing or servicing this stove care should be taken to avoid the possibility of personal injury.