5.3 Provisions for the benefit of the central heating system

Take a temperature in the discharge system of 100 °C into account.
Caution!

5.4 Installing the fire, general

!Caution
A floor plate offers protection against smouldering ash and prevents the soiling of a marble or flagstone floor, for
Tip!
example. We therefore also advise using a fire-resistant floor plate when installing appliances on a wall or ceiling.
Ø
Use the fire's dimensional sketch to see which fire pipe diameter you need (see Annex 1, table 2).
Ø
Use a fire pipe that at least meets the requirements of standards as established in EN 1856-2 T600.
Ø
Install the flue pipes in such a way that a fire hazard can never originate.
Ø
When installing a free-standing fire take account of the minimum required distance from the fire to a
non-combustible wall. This distance amounts to 50 mm.
Ø
When installing the fire and/or flue pipes respect the minimum distance to combustible objects and materials as
shown in Annex 1, table 2.
Ø
Take adequate measures to avoid too high temperatures in any walls behind the chimney breast.
This also applies for materials and/or objects behind the wall.
Ø
Respect the flue duct requirements as described in paragraph. 5.1.2
For any appliance-specific instructions we refer to section 9 'Appliance-specific information'
EN
34
In order to place a free-standing fire with an output of direct heat AND hot water, the following provisions
should be present on the location of the fire:
A water mains connection for the benefit of the safety heat exchanger;
A connection to the water discharge or sewerage for the benefit of the safety heat exchanger and the
pressure relief valve.
A supply and return for the central heating system;
A possible power connection when the pump is used (this pump is an essential part of the system, but is not
part of the scope of delivery!).
Do not make any changes to the fire yourself.
Use clean fabric gloves and avoid fingerprints on the fire and flue pipes.
Depending on the type of suspension, install the fire on a floor, against a wall or on a ceiling with sufficient
load bearing capacity.
Lay a fire-resistant floor plate if the floor is combustible. The floor plate in non-combustible material must
extend at least 300 mm away from the fire and be at least 300 mm wider than the fire. Check these distances
before installation on the basis of applicable national/local laws.