Herunterladen Inhalt Inhalt Diese Seite drucken

Flame Baffle Plate; Adjusting The Door / Replacing Door Seal; Supplementary Installation Instructions Per Appliance; Ivar 10 H2O - Dik Geurts Ivar 10 H2O Installationsvorschrift

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9.3.2 Flame baffle plate

On delivery the flame baffle plate (see Appendix 2, fig. 4, step 1) is located in the top section of the appliance.
In case of maintenance to the appliance, the flame baffle plate has to be removed.
To do this proceed as follows:
Ø
Take hold of the flame baffle plate and push the right side upwards.
Ø
Slide the flame baffle plate over the ridge to the right.
Ø
Lower the left side of the flame baffle plate and remove the flame baffle plate.
Placing the flame baffle plate takes place in reverse order.
The stainless steel profile must be placed at the front with the screw heads facing the top (see Appendix 2, fig. 4
!Caution
step 1).

9.4 Adjusting the door / Replacing door seal

Check the closing of the door during installation or maintenance.
To do this proceed as follows:
Ø
Check the sealing of the door by placing a sheet of paper between the door and the fire. After closing the door, it
should not be possible to pull out the sheet of paper easily. Check the outside of the fire.
If there is insufficient connection (gaps), the door seal has to be replaced. See paragraph 9.5.1.3

9.5 Supplementary installation instructions per appliance

9.5.1 Ivar 10 H
When connecting the fire, proceed as follows (for a drawing of the connections, see appendix 2, figure 1):
NL
38
O
2
Connect the thermal safety valve to the supply (E) of the cooling coil. Make sure the arrow on the safety valve
points towards the connection of the cooling coil.
Connect the discharge of the cooling coil (B) to the water discharge or sewer;
Place the plunger bush for the detector of the thermal safety valve in the water jacket. Slide the detector of
the thermal safety valve (C) in the plunger bush just mounted. Secure the detector with the screw located in
the plunger bush. Connect the return of the central heating water to be heated to the 3/4'' socket; it is
located at the bottom of the water jacket (F). Connect the supply of the heated central heating water to the
socket located at the top of the water jacket (A). Connection D can be used for a temperature sensor. A 1/2"
end cap has been supplied, in case it is not being used.
I N S T A L LA T I ON M A N U A L

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis