9. Appliance-specific information

The appliance-specific instructions as described in this section prevail over the instructions in the other sections! If
!CAUTION
in doubt follow the instructions in section 9 or contact your supplier.

9.1 Smoke control area United Kingdom

The DG Fire Ivar 10 H
wood.

9.2 Air slide valve and flue gas exhaust

9.2.1 Air slide valve

When installing and maintaining the appliance, please check the operation of the air slide valve (see Appendix 2,
fig. 6). It is possible that steel grit entered the air slide valve during transport. If the air slide valve does not move
smoothly it must be cleaned. For this purpose, the air slide valve must be disassembled. The suspended air slide
valve is spring-mounted using a bolt and a spring, which are located below the cover plate.
When mounting the air slide valve, please proceed as follows (see Appendix 2, fig. 6):
If an outside air connection has been mounted, it must first be removed, before the air slide valve can be mounted
Caution!
(for removing the outside air connection: see section 9.5.1.1).
Ø
Remove the vermiculite plates from the bottom (see section 9.3.1).
Ø
Then remove the little square plate located in a recess below the vermiculite bottom plates.
Ø
Loosen the allen screw using the socket head wrench.
As soon as the bolt has been loosened, the air slide valve will fall down. Make sure you catch the air slide valve!
Caution!
Ø
Check the air slide valve and clean it if necessary.
In order to replace the air slide valve, proceed as described for removal, only in reverse order.

9.2.2 Flue gas exhaust

The flue gas exhaust has a 150 mm diameter connection. The connection can be achieved by means of a fixed
pipe of 150 mm.

9.3 Interior lining

9.3.1 Vermiculite

The fire's vermiculite plates are located on the bottom and against the rear and side walls of the appliance
(see Appendix 2, fig. 5).
In the following situations the vermiculite plates must be taken out:
When disassembling the air slide valve (see section 9.2.1).
When replacing the vermiculite plates.
The bottom plates are removed first and the rear plates are removed last.
The insertion of the vermiculite plates takes place in reverse order.
Make sure that the vermiculite plates are placed back in their original position! The back plate, for instance, must
!Caution
be placed with the small, not countersunk, holes towards the front.
O has not been recommended as a suitable for use in smoke control areas when burning