18.5.2 Automatic data entry
In case of automatic input, the dimensions are determined with the electronic gauge. The front
gauge measures the distance value A and the nominal diameter D.
18.5.2.1. Distance value A and nominal diameter D
18.5.2.2. Nominal size W
If your machine is not equipped with a gauge to determine the nominal diameter W,
NOTICE:
enter the value manually (see 18.5.1 Manual data entry).
18.6 Self-Calibration
Entering the wrong dimensions will cause the machine to be incorrectly calibrated
and all subsequent measurements to be incorrect until a new self-calibration with
the correct dimensions is performed.
To self-calibrate the machine, proceed as follows:
1. Mount any wheel on the shaft, even if it is not balanced; better still, if it has an average
size.
2. Set the exact dimensions of the wheel (A, D,
ZIPPER MASCHINEN GmbH
ZI-RWM84
www.Zipper-Maschinen.at
Pull out the gauge until it touches the inner
rim edge.
Hold the gauge until a dashed line appears on
the display A and D (see graphic left).
Return the gauge to its original position.
Display A and D now display the recorded
values.
The gauge must be correctly
NOTICE:
attached to the rim in order to obtain a
precise measuring value.
If an incorrect value was recorded during the
measurement, reposition the gauge against
the rim edge and repeat the procedure.
N O T I C E
W
value).
Press keys Fn and C on the control panel
simultaneously to enter the program.
The display shows US
Press the S
TART
performed and the display shows Add | 100.
Attach the calibration weight (100g) to any
position on the outer side of the rim.
Press the S
TART
OPERATION
. | C
.
R
AL
key. A complete turn is
key again.
42