18.5.1 Manual data entry

When manually entering data, the values are entered with the keyboard on the control panel.
18.5.1.1.

18.5.1.1. Determining and setting the nominal diameter D

18.5.1.1. Determining and setting the nominal size W

ZIPPER MASCHINEN GmbH
ZI-RWM84

Determining and setting the distance value A

www.Zipper-Maschinen.at
 After proper mounting of the tyre on the
threaded
shaft, pull out the special gauge to
the inner rim edge.
 Read the
distance
value A from the scale.
 Enter the
value
using the corresponding Fn
key and the arrow keys (A+/A-) on the
control panel (see chapter 18.3.1 Shortcut
keys).
 The nominal diameter D is indicated on the
tyre (see graphic left).
 Enter the value using the Fn key and the
corresponding arrow keys (D+/D-) (see
chapter 18.3.1 Shortcut keys).
 The nominal sizw is indicated on the tyres
(see graphic left).
Alternatively, use the caliper to determine the
nominal diameter W. For this purpose, place
the heads of the caliper on the left and right
side of the rim and read the value from the
scale on the caliper.
Press
key <T and W+ to activate the manual
entry.
 Enter the value using the corresponding arrow
keys (W+/W-).
OPERATION