[Format] calls the formatting menu
Erase all data ?
[Ok] starts formatting of the card.
Please wait
Memo Card Formatting
Prior to storing arbitrary signals an unused card
must be formatted.
Formatting is done in menu 2, item [Format]. The instrument
reads automatically the memory capacity of the card. With some
STOP
older cards it may be necessary to specify the capacity in
advance. The buttons [+ kB –] select the capacity which will be
entered by pressing [Ok]. In order to stop this procedure [No] has
to be depressed. The HM8131-2 is able to format cards from 64k
STOP
to 1 MB.
A formatted 1 MB card will accept up to 114 4k- or up to
TiPP
31 16k – signals.
Memory menu [Memo]
Memory Menu HM8131-2
* CONFIG IN MEMORY *
Recall
The HM 8131-2 can store up to 10 complete instrument set-ups.
Each such configuration will include all parameters which were
defined resp. active at the moment of storage, such as frequency,
amplitude, function, offset, modulation type etc. with the exception
of arbitrary signals. Any configuration stored may be called at any
time.
In order to store a configuration call first the menu "CONF IN
MEMORY, item (Store).This will show a display with an indication
of available locations (0 ... 9). By selecting a location the
configuration will be automatically stored there. Calling a
configuration requires the same procedure.
Storing of instrument configurations
** OPTIONS MENU 1 **
Com Mcard Memo -->
Subject to change without notice
Downloaded from
www.Manualslib.com
No
Ok
Store
* Store
Memory *
Number :
?
* Recall
Memory *
Number :
?
manuals search engine
[Memo] will call this display:
* CONFIG IN MEMORY *
Recall
Store
[Store] will advance to:
*
Store Memory
Number: 1
Upon selection of the location the configuration will be stored.
Calling of configurations
** OPTIONS MENU 1 **
Com Mcard Memo -->
[Memo] will advance to:
* CONFIG IN MEMORY *
Recall
Store
[Recall] calls the location of the set-up
*
Store Memory
Number: 2
After specifying the location the instrument will load the
configuration

5.44 Options menu 2

Options Menu 2 HM8131-2
** OPTIONS MENU 2 **
<-- Beep Enco -->
** ENCODER SETUP **
** BEEPER SETUP **
Soft Loud None
Options menu 2 allows to set parameters for the acoustical signal
[Beep] and the knob [Enco].
Acoustical signal
The beep will signal each pushbutton activation and will also
sound off in case of mistakes. Activation and selection of volume
is done in the menu "BEEPER SETUP", The volume may be
chosen from None over Soft to Loud.
Activation of the knob
The menu "ENCODER SETUP" allows to turn the knob function
on [ON] or off [OFF].
MainMenu 2 and its functions
*
*
On
Off