Herunterladen Inhalt Inhalt Diese Seite drucken

Energy Efficiency - ZANKER KOU20611 Benutzerinformation

Vorschau ausblenden Andere Handbücher für KOU20611:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Cable
Cable types applicable for installation or replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05 V2V2-
F (T90), H05 BB-F
For the section of the cable refer to the total power on
the rating plate.
Connecting the terminal board
The appliance has a six-pole terminal board. The
jumpers (bridges) are set for operation on a 400 V
three-phase with a neutral wire.
1
2
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different, rearrange the jumpers
on the terminal board (refer to the connection diagram

Energy efficiency

Product Fiche and information according to EU 65-66/2014
Supplier's name
Model identification
Energy Efficiency Index
Energy efficiency class
Energy consumption with a standard load, conventional mode
Energy consumption with a standard load, fan-forced mode
Number of cavities
Heat source
Volume
Type of oven
Mass
16
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
3
4
5
below). Connect the ground cable to the terminal. After
you connect the supply cable to the terminal board,
attach it with a junction clamp.
1 2 3 4 5
230V 3~
L1
1 2 3 4 5
230V 1~
L1
1 2 3 4 5
400V 2N~
L1
1 2 3 4 5
400V 3N~
L1 L2 L3
Zanker
KOU20611XB
105.2
A
0.83 kWh/cycle
0.81 kWh/cycle
1
Electricity
53 l
Built-Under Oven
28.1 kg
L2
L3
PE
N
PE
L2
N
PE
N
PE

Werbung

Kapitel

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Kou20611xb

Inhaltsverzeichnis