Prevention of ESD
To fulfill the requirements in
IEC61340-5-1 the controller shall be
placed more than 30 cm away from the
ESDS (Electrostatic sensitive devices).
If that is not possible the display shall
be treated with an antistatic agent
before the controller is brought in to the
EPA (Electrostatic Protected Area) and
regulary during use.
Differential circuit breaker
The controller is equipped with a differential
circuit breaker to protect the operator from
electric shock.
A differential circuit breaker in the power supply
to the controller detects any insulation defect
between the phases of the network and the earth
and immediately cuts off the power supply.
Fuse
The fuse on the electronic board is a 1Amp/slow
blow 250V BK/ETF1A from Bussmann.
This fuse should only be changed by qualified
service personnel. Replace only with a fuse of
same reference.
Tool care and service
Only experienced and qualified
personnel (authorised electricians) are
entitled to open and have access to the
inside of the controller.
If in doubt, return the tool to a Desoutter-
authorized service centre (contact your local
Desoutter Sales for details).
Disconnect from power supply and wait
10 minutes before commencing service
operations.
Failure to wait 10 minutes may result
in electric shock from undischarged
capacitors.
According to Directive 2012/19/CE
concerning Waste Electrical and
Electronic Equipment (WEEE), this
product must be recycled.
● Contact your Desoutter
representative or consult the
website "www.desouttertools.
com" to find out where you can
recycle this product.
09/2019
INSTALLATION
(See page 5).
Although our cables are designed
to work under drastic conditions, we
recommend that you check the following
points for longer service life:
● Bending radius should not be lower
than 10 times the cable diameter
(D-c).
● Friction with the outer sheath should
be restricted (D-b).
● Any direct pull on the cable should be
avoided (D-a).
The controller should be installed in such
a way that it should be easily switched
off.
Fieldbus module
G
See page 7.
When the fieldbus module is not into its
location, the cover must remain in place.
DESOUTTER TOOL AND ACCOUNT
SERVICES
From the installation and set-up to the full life
cycle of your product, we offer a wide range of
products to keep your equipment and processes
operating at maximum levels.
Consult your local Desoutter Customer Service
Center to find out how we can deliver a lifetime of
Peace of Mind™ and optimal operation.