Installation
Hook up data:
Earth conductor
terminal, green/yellow
(PE) and row terminal,
blue (cable N)
Stripping length
Kind of wire
Cable cross section
Torque
Use suitable tools for
installation!
Cord grip range: 9 - 17 mm
Cable diameter
Power cable
at least 5x4 mm² Cu
Torque to 8 Nm
see Figure 13
Figure 5: Preparation of the cables and hook up (exemplary)
36
Contactor connections
11 - 13 mm
single wire or wire strand
or wire strand with ferrules
2
4 - 6 mm
3 - 4.5 Nm
Cord grip
9 - 17 mm
10
The earth conductor must have such
a length that it will tear off only after
the other cables.
Terminals with
ferrules
12 mm length
blue
green/yellow
200
260
Thermo AC 2nd generation
Cable gland
for control line
(M12x1.5)
Cable gland
for power
cable (M25x1.5)
brown
black
grey