symbol (NEG,N,-). Do not make any connections to
the carburetor, fuel lines, or thin, sheet metal parts. The
below instructions are for a negative ground system
(most common). If your vehicle is a positive ground
system (very uncommon), follow the below instructions
in reverse order.
1.) Connect the positive (red) battery clamp or eyelet
terminal connector to the positive (POS,P,+) battery
terminal.
2.) Connect the negative (black) battery clamp or eyelet
terminal connector to the negative (NEG,N,-) battery
terminal or vehicle chassis.
3.) Connect the battery charger's AC power plug into a
suitable electrical outlet. Do not face the battery when
making this connection.
4.) When disconnecting the battery charger, disconnect
in the reverse sequence, removing the negative first (or
positive first for positive ground systems).
Begin Charging.
1.) Verify the voltage and chemistry of the battery.
2.) Confirm that you have connected the battery clamps
or eyelet terminal connectors properly and the AC power
plug is plugged into an electrical outlet.
3.) The charger will begin in Standby mode, indicated by
an orange LED. In Standby, the charger is not providing
any power.
4.) Press the mode button to toggle to the appropriate
charge mode (press and hold for three seconds to enter
an advanced charge mode) for the voltage and chemistry
of your battery.
5.) The mode LED will illuminate the selected charge
mode and the Charge LEDs will illuminate (depending on
the health of the battery) indicating the charging process
has started.
6.) The charger can now be left connected to the battery
at all times to provide maintenance charging.
8