7. Technical data

Model
Power consumption max. (kW)
Current consumption (A)
Air flow rate cum/h (max.)
Air flow rate cum/h (NLV at 250 PA)
Compression (Pa) max.
Electric connection (V/Hz)
Volume 3m dB(A)
Height / Width / Depth (mm)
Weight (kg)
Hose (diam. in mm)
Hose length max. (m)
CAUTION: Within the scope of further development, technical data may be changed without prior
announcement. Some values are approximate values.

8. Fault finding and correction

WARNING: Maintenance work shall have to be carried out with the unit switched off, i.e. with mains
plug removed.
PROBLEM
Motor is not operating
The motor is running, but
the impeller turns
irregularly or makes contact
Unit vibrates excessively
B = User | AST = Authorised service technician
Ask your local dealer for spare parts or get in touch with HEYLO service department.
CAUSE
No power to unit.
The unit has not been switched
on.
Impeller is blocked.
Air inlet or outlet is blocked.
Switch has broken off.
Loose wiring.
A heavy impact has bent the
motor suspension so that the
impeller jams.
A heavy impact has caused the
motor
to
slip
out
of
suspension so that the impeller
jams.
Collection of dirt on the wheel.
Unbalance of the impeller.
Impeller is bent.
Motor shaft is bent.
PowerVent 3000
0.62
2.9
4200
1550
550
230/50
78
530 / 400 / 520
17.5
305
45
Versi
SOLUTION
on
B
Connect the unit; check the fuse.
B
Switch the unit on.
B
Remove the reason for the blockage.
B
Switch the unit off and let it cool down; then
remove blockage.
AST
Order replacement switch from the dealer or
HEYLO.
AST
Check wiring and tighten, if required.
AST
Remove the motor from the housing, replace
or repair the bent motor suspension.
AST
Remove the motor from the housing, then
the
place the motor in the suspension correctly.
B
Clean impeller.
AST
Balance or replace the impeller.
AST
Replace impeller.
AST
Replace motor.