7. Technical data

Type
Air flow rate max. (m³/h)
Compression (Pa)
Power connection (V/Hz)
Electrical protection (A)
Power consumption max. (kW)
Protection class (motor/housing)
Height x Width x Length (mm)
Weight (kg)
Sound level dB(A) 3m
Hose connection on both sides Ø mm
CAUTION: Within the scope of further development, technical data may be changed without prior
announcement. Some values are approximate values.

8. Fault finding and correction

WARNING:
Maintenance work shall have to be carried out with the unit switched off, i.e. with mains plug removed.
PROBLEM
Motor is not operating
The motor is running, but
the impeller turns
irregularly or makes contact
Unit vibrates excessively
B = User AST = Authorised service technician
Ask your local dealer for spare parts or get in touch with HEYLO service department.
CAUSE
No power.
The unit has not been switched
on.
Impeller is blocked
Air inlet or outlet is blocked.
Switch has broken off.
Loose wiring.
A heavy impact has bent the
motor suspension so that the
impeller jams.
A heavy impact has caused the
motor to slip out of the
suspension so that the impeller
jams.
Safety broken due to excessive
load on the fan wheel.
Collection of dirt on the wheel.
Unbalance of the impeller.
Impeller is bent.
Motor shaft is bent.
VORTEX 3000
3,600
550
230 V / 50 Hz
2.2
0.49
IP 44
490 x 480 x 400
15
83
305
by
SOLUTION
B
Connect the unit; check the fuse.
B
Switch the unit on.
B
Remove the reason for the blockage.
B
Switch the unit off and let it cool down; then
rRemove blockage.
AST
Order replacement switch from the dealer or
HEYLO.
AST
Check wiring and tighten, if required.
AST
Remove the motor from the housing, replace or
repair the bent motor suspension.
AST
Remove the motor from the housing, then place
the motor in the suspension correctly.
AST
Safety splint must be replaced
B
Clean impeller.
AST
Balance or replace the impeller.
AST
Replace impeller.
AST
Replace motor.