6 Troubleshooting

Always secure the machine according to
regulations during lifting or transport by a vehicle
or suitable devices and strap down with tension
belts.
For longer periods in transport or in storage, the
"
machine needs to be covered to protect it
against soiling.
6 Troubleshooting
Only suitably knowledgeable, qualified professional technicians may perform repairs on the machine.
Fault
The machine does not
start.
The grinding pattern is un­
even.
The machine shuts down
independently.
Cause
The voltage supply has not been prop­
erly connected.
The connecting cable is defective.
Faulty mains connection.
A safety switch is defective.
The tool is loose.
The pad, brush, or the grinding wheel
is damaged or worn.
The machine is overloaded.
The drive overload protection has trig­
gered.
The extension cable's cross section is
too small.
Remedy
Connect the connecting cable (exten­
sion cable) with a proper power socket.
Replace the connecting cable.
Use a different power socket if neces­
sary.
Replace the safety switch.
Fasten the tool.
(! Chapter 4.2, page 19).
Replace the pad, brush, or the grinding
wheel.
(! Chapter 4.2, page 19).
Reset:
a.
Wait 2 ... 3 minutes.
b.
Restart the machine
(! Chapter 3.1).
If the drive overload protection
trips repeatedly, the load on the
machine needs to be reduced
(mount other tools if necessary),
otherwise motor damage could re­
sult!
Check the extension cable and replace
if necessary.
21