Herunterladen Inhalt Inhalt Diese Seite drucken

Site And Installation Safety - VOSS.farming Sunny 200 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Sunny 200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
200
► Incorrectly installed electric fences with stronger current can cause electric
shocks that lead to loss of muscle control. An electric shock can cause painful
muscle spasms that can break bones and dislocate joints.
Info
Please note that the following specifications regarding the marking of electric
animal fences are country‑specific. Please follow the regulations of your
respective country.
► In order to warn outsiders of possible dangers, electric animal fences that run
along a public road or path must be clearly signed at frequent intervals. These
warning signs must be clearly visible and attached to the fence posts or the
fence itself. Warning signs must adhere to the following guidelines:
Minimum size of 100 mm x 200 mm
Black lettering (min. font size of 25 mm, on both sides, non‑erasable) on
a yellow background with the analogous content „ATTENTION ELECTRIC
FENCE" and/or the symbol shown in the illustration:
► Whenever an electric animal fence crosses a public footpath, a non‑electrified
gate must be erected at this point or an overpass must be available. Electrified
wires lying nearby must also be marked with warning signs.
► In general, warning signs must be placed at each gate or access point and at
intervals of max. 10 m.
2.2

SITE AND INSTALLATION SAFETY

► The following minimum distances must be observed when installing
connection lines and electric animal fences near high-voltage lines:
► When installing connection lines and electric animal fences near a high-
voltage line, they may only be installed at a maximum height of 3 m above
the ground. This height must be maintained on each side of the vertical
projection of the outer conductor of the high‑voltage line on the ground. The
following distances apply:
2 m for high‑voltage lines with a nominal voltage up to 1,000 V
15 m for high‑voltage lines, with a rated voltage of more than 1,000 V
22
WARNING
ELEKTROZAUN
ELECTRIC FENCE
CLÔTURE ÉLECTRIQUE
SCHRIKDRAAD
ELEKTRISK HEGN
ELEKTRISKT STÄNGSEL
RECINTO ELETTRICO
CERCADO ELECTRICO
ЭЛЕКТРОИЗГОРОДЬ
Voltage of the power line
≤ 1.000 volts
> 1.000 ≤ 33.000 volts
> 33.000 volts
INSTRUCTION MANUAL VOSS.FARMING SUNNY 200
Air Gap
3 metres
4 metres
8 metres
42082| 09 | 2020 | V2