Herunterladen Inhalt Inhalt Diese Seite drucken

Lincoln Quicklab 236-13891-1 Benutzerinformation, Betriebsanleitung Seite 35

Steuerplatine für pumpe 203
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Subject to modifications
Connection X1: Bayonet plug DIN 72585-1, 7/6-pole (left) 2A7.16
1A1:
Socket (without cable) for power supply 110-240 VAC ±10%, 50/60 Hz ±5%
2A7.16: Socket to connect the illuminated pushbutton (for addit ional lubrication and functional test) and the machine contact
as well as the control light for the low level indication
15
- Power Supply + 24 VDC via machine contact
30
- bridged with 15
31
- – 0 VDC
A
- Control p.c.b. V10-V13
B
- Pump housing
C
- Connection plug 2A7.16 at pump housing
D
- Socket X1
F
- Machine co ntact
X
- Bypass as an option to machine contact F
Connection X2: Square-type plug DIN 43650 , 3/3-pole (left) 1A1
G
- Fuse 10 A
H
- External illuminated pushbutton
M
- Electric motor
N
- Level control
O
- external signal lamp in case of low-level indication
T-PCB vb7 -050e08
br
- brown
gb
- yellow
sw
- black
ws
- white
rt
- red
bl
- blue
gn/gb - green/yellow
gr
- grey
U
- Power supply board
V
- Socket X2
W
- Connection plug 1A1 at the pump housing
Z
- Operational test / additional lubrication

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis