Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning The Working Area And Drawer; Cleaning The Exterior Housing; Cleaning The Inside Of The Folding Cover; Repair - HellermannTyton M-BOSS Compact Betriebsanleitung

Edelstahlprägesystem
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Servicing
4 Using a lint-free cloth, apply a thin coat of multifunction
oil on the guide rods of the X- and Y-carriages.
5 Swivel the bridge back.
6 Close the folding cover.
; The guide rods are clean and lubricated.

8 .2 .5 Cleaning the working area and drawer

Proceed as follows:
1 Open the folding cover.
2 Clean the working area with a lint-free cloth and a mild
cleaning agent.
3 Close the folding cover.
4 Open the drawer.
5 Clean the drawer with a lint-free cloth and a mild
cleaning agent.
6 Close the drawer.
7 Insert the mains plug into the socket.
8 Switch the device on again using the main switch.
; The working area and drawer are clean.

8 .2 .6 Cleaning the exterior housing

Proceed as follows:
f Clean the exterior housing of the device with a lint-free
cloth and a mild cleaning agent.
; The housing exterior is clean.

8 .2 .7 Cleaning the inside of the folding cover

Proceed as follows:
1 Open the folding cover.
2 Clean the inside of the folding cover with a lint-free cloth
and water or a mild cleaning agent.
3 Close the folding cover.
4 Insert the mains plug into the socket.
5 Switch the device on again using the main switch.
; The inside of the folding cover is clean.

8 .3 Repair

Servicing includes the repair and replacement of compo-
nents. It is only necessary when components have been
misaligned or damaged by external influences.
24

8 .3 .1 Adjusting the gripper

If the marker is not correctly positioned in the gripper,
the closing of the gripper can be adjusted using the stop
bolt.
Proceed as follows:
1 Open the folding cover.
2 Increase or decrease the distance of the stop bolt in
small increments.
1
Distance of the stop bolt.
1 Stop bolt
• Small distance: the gripper closes later
• Large distance: the gripper closes earlier
3 Close the folding cover.
; The gripper closes properly again.

8 .3 .2 Relieving the embossing drum

In case of unintentional opening of the folding cover,
power outages or blockage of the embossing drum, the
embossing process can stop unexpectedly.
Proceed as follows:
1 Switch off the device using the main switch.
2 Open the folding cover.
3 Perform a visual check for foreign objects.
4 Remove any foreign objects.
5 Close the folding cover.
6 Switch on the device with the main switch.
7 Select the "Restore" function field in the Metal Printer
Monitor.
; The device moves to its basic position.