GENERAL EN12941 / EN14594
2.1
This product may only be used by qualified persons who are fully aware of the dangers in the workplace and
are familiar with the use and handling of the device.
2.2
Respiratory protection equipment must be selected according to the type and concentration of hazardous
substances.
2.3
Insufficient warning properties of hazardous substances require special rules of use.
2.4
If the Face Seal does not fit correctly the pressurization required for the protection factor required will not
be achieved. The required protection factor can only be achieved when the Multimask Pro fits correctly.
2.5
The seal of the mask to the face must be assured. The required seal cannot be achieved if beard, hair, certain
hairstyles, deep scars, spectacle frames or items of clothing intervene between the seal and the face. (Spec-
tacles with a special frame can be supplied if requested.)
2.6
Before entering a contaminated room the mask seal must be tested in accordance with Paragraphs 3.3.1
and 3.3.2. The required degree of protection can only be achieved when the Multimask is correctly fitted.
2.7
If the respirator is used in areas with a risk of explosion, the relevant regulations must be observed.
2.8
The Multimask Pro must be used with the blower unit running. If the blower is not operating, none or only
a small respiratory protection function of the device can be expected. There is a danger of an immediate,
strong accumulation of carbon dioxide. A blower unit failure is considered to be an exceptional condition.
2.9
Take care that the breathing hose does not catch on nearby objects because the danger exists that the hose
can lose its airtight seal.
2.10
During strong breathing under high workload a negative pressure can develop in the respiratory connec-
tion during the inhalation phase, which can lead to the penetration of contaminations.
2.11
Using the equipment in high wind speed environments may reduce the protection factor.
2.12
The Multimask cannot be used in case of difficulty breathing, if you perceive smell or taste of contamination
or if you feel some kind of discomfort (dizziness, nausea or similar).
2.13
If you are unsure about the selection and handling of the equipment, please contact your supervisor or the
point of sale.