Connector diameter Ø200 mm ext.
Type approved in accordance with:
European standard EN-13229
DIN plus
Bauart 1
15A B-VG
Test report no.
N-27: RRF-29 09 2050,
N-30: RRF-29 09 2051
Structural support
Check that wooden joists have the sufficient load
capacity for the insert, chimney and construction parts
that are used when recessing. A completed installation
can usually be positioned on a normal wooden joist in a
single-family house as long as the total weight does not
exceed 400 kg.
Hearth plate
If the floor under the stove is flammable, it must be
protected by a non-flammable material e.g. natural
stone, concrete or 0.7 mm thick metal. The floor in front
of the hearth opening must be protected against any
falling embers using non-flammable material that
covers an area at least 300 mm in front and 100 mm
along each side of the hatch opening. A painted metal
or toughened glass hearth plate is available as an
accessory.
Hearth cladding
16
Diffuser
Smoke baffle
Damper
Type plate
Chimney
The insert requires a draft in the chimney of at least
–12 Pa. The draft is affected both by the length and
area of the chimney, and by how well sealed it is.
To enable lighting with the hatch open, the minimum
recommended chimney length is 3.5 m and suitable
cross section area is 300 cm² (200 mm in diameter).
When connecting, via adapter (accessory), to a
chimney with a diameter of Ø150 the insert must
always be lit with the hatch closed. Carefully check
that the chimney is sealed and that there is no leakage
around soot hatches and flue connections. Note that a
flue with sharp bends and horizontal routing reduces
the draught in the chimney. Maximum horizontal flue
is 1 m, on the condition that the vertical flue length
is at least 5 m. It must be possible to sweep the full
length of the flue and the soot hatches must be easily
accessible.
Connector
Ash-pan
Bottom insulation
GB
Counter
weight
Grate
Service hatch
Adjustable feet